It looks like someone tried implementing remote request frames and that got merged into the library... https://github.com/Seeed-Studio/CAN_BUS ... a9b22b0ca2

As for the LEDs, that is probably because you do not have two active CAN nodes, just one, which means that the protocol controller is trying to send that message and there is no other node to acknowledge that it was sent so the controller retransmits it again, and again waiting for the acknowledge. If you take the bit rate down to 5KBPS, there might be some noticeable flashing.

Statistics : Posted by matthew.hammond85 • on Sun Sep 14, 2014 3:52 am • Replies 1 • Views 46